KAVAN C100 Duo charger with balancer, 2× 500W
Tuesday 24.11. it can be at your place
Customer line 9 am - 6 pm: +420 774 590 258 | Do you need help?
| Price in e-shop with VAT: | 16,35 € |
|
Stock
Monday 23.11. you can have it at the Nademlejnská central store Tuesday 24.11. it can be at your place |
|
|
|
Buy |
| Buy | |
|
We have been on the business for 35 years = safe shopping and professional services |
|
Don't know how to choose? Are some parameters not clear to you? Write us your question and we will contact you with an answer.
Send a questionSeven-cell Kavan NiMH 8.4 V power battery pack with a capacity of 1100 mAh and a 10C discharge rate, arranged in a stick configuration. The battery is supplied without a power connector. Dimensions: 123×46.5×24 mm, weight: 226 g.
Kavan Standard series NiMH packs are assembled from nickel-metal hydride batteries that allow fast charging and discharging. Receiver packs are supplied with a lead/charging cable featuring a standard JR/UNI connector; power packs are supplied without connectors. They are designed to power smaller RC models of all kinds or to supply power to their onboard electronics.
Installing the battery
Protect the battery from vibrations, impacts and shocks that may occur during the operation of RC models (by wrapping it in foam rubber or a similar material). Secure it, for example, with hook-and-loop fasteners or cable ties, so that it cannot come loose in flight. Place the battery in an easily accessible location in the model, where it will be protected from fuel, exhaust gases, operating fluids or water getting inside.
Using the battery
The batteries are designed to power small RC models or supply power to the onboard electronics of smaller RC models that do not require a high current load. A typical application is a setup consisting of a receiver and 3–4 standard-size servos (approx. 3–4 kg/cm of torque) or smaller servos for 1050 mAh battery packs, or 2–4 micro servos or pico servos for 350 and 650 mAh battery packs. If your onboard electronics include more servos or larger servos, use batteries with a higher current rating. Otherwise, the batteries may be unable to handle current peaks, and the voltage drop under excessive load could cause the receiver to stop working, risking a model crash.
Charging the battery
Fully charge the battery before first use. We recommend slow-charging receiver batteries “overnight” at a rate of 0.1C, i.e. 100 mA for a 1050 mAh battery. In this case, the batteries can be charged safely without removing them from the model. If you need to charge them faster for any reason, always remove the batteries from the model before charging. Due to the current ratings of the connector, cable and batteries, we do not recommend using a charging current above 0.5C. Do not charge power batteries at a rate higher than 1C. The battery temperature during charging should not exceed 40 °C (the battery should feel warm, not hot, to the touch).
Forming the batteries
To bring a new battery into optimal operating condition, we recommend performing an initial conditioning process consisting of 3–5 cycles of slow charging at 0.1–0.2C and discharging at a maximum of 1C. The amount of charge put in is not very important; the amount discharged is the decisive value. Stop conditioning once the amount discharged has practically stopped changing (individual values should be within approximately 5–10%). We recommend following the same procedure after the batteries have been stored out of use for an extended period (several months).
Discharging the batteries
If you use slow “overnight” charging at a rate of 0.1–0.2C, there is no need to discharge the batteries before every charge. However, we recommend fully discharging the batteries every 3 months (to 1.0 V per cell, i.e. 4.0 V for a four-cell pack) and then fully charging them again to keep them in optimal condition.
If you use faster charging, we recommend fully discharging the batteries before charging (to 1.0 V per cell, i.e. 4.0 V for a four-cell pack). If the batteries warm up during discharge, allow them to cool to ambient temperature before charging. During operation, the batteries should not heat up above approximately 60 °C (the battery feels hot to the touch, but can still be held in your hand). If this occurs, you should either change the battery's operating conditions (reduce the current draw) or use batteries with a higher current rating.
Storing the batteries
NiMH batteries should be stored fully charged. If you know you will not use the batteries for more than 3–4 weeks, fully charge them and store them in a dry place at normal room temperature. For long-term storage out of use, we recommend fully discharging the batteries every 3 months (to 1.0 V per cell) and then fully charging them again. Please remember that a battery's ability to retain its charge depends strongly on the temperature at which it is stored. At room temperature, a properly maintained battery will still retain approximately 60–70% of its charge after 1 month, while at 40 °C it may retain only 20–30%.
| Capacity [mAh] | 1100 |
| Voltage [V] | 8,4 |
| Charging current [mA] | 110 |
| Max. charging current [A] | 1,1 |
| Max. discharge current [A] | 11 |
| Low self-discharge | No |
| Length [mm] | 123 |
| Width [mm] | 46,5 |
| Height [mm] | 24 |
| Weight including cable [g] | 226 |
1 item