Product inquiry
Foxy lead-acid (Pb) battery 12 V/4.5 Ah
Goods code: 3EB8025
Set availability monitoring
Foxy lead-acid (Pb) battery 12 V/4.5 Ah
Goods code: 3EB8025
Foxy lead-acid (Pb) battery 12 V/4.5 Ah
| Price in e-shop with VAT: | 16,35 € |
| Temporarily unavailable | |
|
|
Send a question
on availability |
|
Send a question
on availability |
|
|
35 years in business = safe shopping and professional service |
|
Don't know how to choose? Are some parameters not clear to you? Write us your question and we will contact you with an answer.
#Chcete dostat upozornění ve chvíli, kdy produkt bude k dispozici? Stačí vyplnit formulář a náš hlídací pes Vám dá vědět.
-
Product Description
-
Technical Data:
Product Description
FOXY 3EB8025 - Foxy lead-acid (Pb) battery 12 V/4.5 Ah
12 V maintenance-free lead AGM battery with reversible valves and terminals for FASTON 4.8 mm connectors.
Foxy maintenance-free lead batteries use modern AGM (Absorbent Glass Mat) technology, with electrodes separated by a non-woven glass fibre separator saturated with electrolyte. The battery is completely sealed in an ABS plastic case, so under normal conditions there is no risk of electrolyte spillage. A safety valve protects against explosion in the event of overloading during charging or discharging.
Battery installation
Protect the battery against vibrations, impacts and shocks that may occur during operation of RC models or when installing it in portable equipment (starter boxes, etc.) by wrapping it in foam rubber or similar material. Secure it in an easily accessible place where it will nevertheless be protected against fuel, exhaust gases and other operating fluids or water getting in.
The batteries are fitted with standard terminals for FASTON 4.8 mm (0.187“) connectors. The terminal sealed in red epoxy resin is positive (+), while the terminal sealed in black resin is negative (-). Lead batteries are HEAVY, so make sure your battery holder is strong enough.
General principles for handling and discharging lead batteries
The maximum peak discharge current must not exceed ten times the numerical value of the battery’s rated capacity (10C), and the continuous discharge current should not exceed 3C. For example, the maximum discharge current of a 3 Ah battery is 10×3=30 A, and the continuous current is 9 A.
Deep discharge causes permanent damage to the battery and significantly shortens its service life. You can prevent this by never fully discharging the battery (not below 1.8 V per cell), always switching off connected electrical equipment after use, and recharging the battery in good time.
Charging for cyclic and standby operation
Charging should be carried out in constant current–constant voltage ("CC/CV") mode. This means that the charger must operate so that the maximum permissible charging current and maximum charging voltage are not exceeded. The maximum charging voltage depends on how the battery is used and on the temperature. It may be higher (2.40–2.50 V per cell) for cyclic operation involving full charge/full discharge, which is typical when using the battery to power models, electric starters, power panels, etc.
In standby mode, when the battery is kept fully charged at all times (UPS backup power supplies, emergency lighting power supplies, etc.), the maximum permitted voltage is lower (2.26–2.30 V). The higher the ambient temperature, the lower the permitted end-of-charge voltage.
If you do not have an automatic charger for lead batteries that accurately monitors the charging process and automatically keeps the current and end-of-charge voltage within the permissible limits, use only “slow charging” at a current of 0.1C, i.e. a current numerically equal to one tenth of the battery’s rated capacity. Example: 10 Ah battery – slow charging at 0.1C = 10 (Ah) / 10 = 1 A. At this current, it takes approximately 14 hours to charge a fully discharged battery. Charging should be stopped immediately once this time has elapsed.
Battery service life
As soon as a battery is manufactured, it begins to undergo natural ageing, which causes its performance to deteriorate, regardless of whether or not it is in use. Its service life depends heavily on its mode of use (cyclic/standby), load level, depth of discharge, operating temperature and humidity, etc. For example, tests of Foxy batteries under laboratory conditions at temperatures of 20–25 °C show a typical service life of over 1,000 cycles when discharged to 70%, over 400 cycles when discharged to 50%, and over 200 cycles when discharged to 100%.
Storage
Store the batteries fully charged in a dry environment at a temperature of +5 °C to +30 °C and a maximum humidity of 50%. At a storage temperature of 25 °C, self-discharge is approximately 3% per month. If the batteries are stored for longer than 1 year, they must be fully recharged before use.
Technical Data:
| Capacity [mAh] | 4500 |
| Voltage (nominal) [V] | 12 |
| Voltage (end-of-charge for cyclic operation) [V] | 14,4–15 |
| Voltage (end-of-charge for backup use) [V] | 13,6–13,8 |
| Charging current (max.) [A] | 1,35 |
| Discharge current (continuous) [A] | 13,5 |
| Discharge current (peak) [A] | 45 |
| Internal resistance (fully charged, at 25 °C) [mOhm] | 35 |
| Length [mm] | 90 |
| Width [mm] | 70 |
| Height [mm] | 101 |
| Height (overall, including terminals) [mm] | 107 |
| Weight [g] | 1700 |